Compare

6SL3546-0FB21-1FB0 SINAMICS G120D CU250D-2 PN-F PP

SINAMICS G120D CU250D-2 PN-F PP

We will send you the price and availability by email without delay
Unit:pcs
Code 1:SI_6SL3546-0FB21-1FB0
Code 2:6SL3546-0FB21-1FB0
Warranty:12
Warranty for companies: 12

Description

SINAMICS G120D Control Unit CU250D-2 PN-F PP PROFINET and Safety Integrated with positioning capability (EPOS) in push-pull version 6 DI/3 F-DI, 2 DO/1 F-DO, 2 AI SD/MMC card interface HTL and SSI encoder interface Degree of protection IP65 Ambient temperature 0 to +50 °C without Power Module SINAMICS CU250D-2 Control Unit for the SINAMICS G120D distributed inverter. The Control Unit performs closed-loop control functions for the inverter. In addition to the closed-loop control, it has additional functions that can be adapted to the particular application through parameterization. CU250D‑2 Control Units can be used to implement applications with positioning requirements in the drive. This expansion opens up their use in lifting, swiveling, traversing or rotating applications. The positioning functionality is comparable to that of SINAMICS S110 servo drives. However, the following notes must be observed in this context: On the one hand, vector control and sensorless vector control are supported, on the other hand, positioning is possible via one encoder or in parallel using two encoders. The Control Units are available in different versions, for example, in CU250D-2 DP-F, CU250D-2 PN-F, CU250D-2 PN-F PP (Push Pull: Alternative connection method for the 24 V DC supply voltage and the PN communication) and CU250D-2 PN-F FO (Fiber Optic). With the fail-safe variants of the CU250D-2 series, the fail-safe SINAMICS G120D inverter provides five safety functions: Safe Torque Off (STO) to prevent the drive from performing active movements, Safe Stop 1 (SS1) for continuous monitoring of a safe braking ramp, Safely Limited Speed (SLS) for preventing dangerous movements when exceeding a speed limit, Safe Direction (SDI) and Safe Speed Monitoring (SSM). An external 24 V DC power supply is required in order to operate the Control Unit. SINAMICS - the integrated drive family for every field of application.

Technical specification

Ratings

You have already rated the product

Zboží bylo vloženo do hromadné poptávky

{common::4::askForPriceAddError}

Price inquiry

I am interested in the price and availability of this product.

Acceptance with the processing of personal data is mandatory.

Poptávku na cenu se nepodařilo odeslat
Poptávka na cenu byla odeslaná
Login to the newsletter was successful.
Something is wrong, contact us.

Košík obsahuje nepovolené položky

Košík je prázdný

Show basket

The article was added to comparison

Please wait...
Unable to complete your order, please try again later
Chyba při vložení do košíku
Nepovolená kombinace - košík obsahuje dárek z věrnostního programu, který je možné uplatnit pouze v samostatné objednávce.
Chyba při odebrání z košíku
Dárek lze uplatnit pouze v samostatné objednávce.
Dárek lze uplatnit pouze s nákupem alespoň jedné položky.
Máte blokované čerpání bodů
Error adding gift to cart
Pro vložení do košíku nemáte dostateční počet bodů
Dárek není skladem
Požadavek nemůže být odeslán. Zkuste to znovu později